All Analytical Energy Testing Services
Test NameMethodQuantityWikipedia ReferenceMethod Link
Acid and Base Number by Color-Indicator TitrationASTM D974100mlView DescriptionView Method
Acid NumberASTM D664300mlView DescriptionView Method
Acidity in Aviation Turbine FuelASTM D3242100ml View Method
Acidity of EthanolASTM D161350mlView DescriptionView Method
API GravityASTM D405220mlView DescriptionView Method
Ash in BiomassASTM E17551 gramView DescriptionView Method
Ash in WoodASTM D11022 grams View Method
Ash, TotalASTM D482100ml View Method
BTU DeterminationASTM D58652g View Method
Calorific Value (BTU)ASTM D24020mlView DescriptionView Method
Carbon, Hydrogen, Nitrogen, OxygenASTM D537310g View Method
Carbon, Hydron & NitrogenASTM D529110gView DescriptionView Method
Cetane IndexASTM D976350mlView DescriptionView Method
Chloride & Sulfate by ICASTM D731920mlView DescriptionView Method
Cloud PointASTM D250080mlView DescriptionView Method
Cold Filter Plugging Point (CFPP)ASTM D6371, EN 116, IP 30980mlView DescriptionView Method
Cold Soak FiltrationASTM D6217, ASTM D7321300ml  
Copper Strip CorrosionASTM D13050ml View Method
Density (lb/gal or kg/L)ASTM D405220mlView DescriptionView Method
Determination of Ash Content of Wood FuelsASTM E15345gView DescriptionView Method
DistillationASTM D86200mlView DescriptionView Method
Ethanol PurityASTM D550125mlView DescriptionView Method
Flash PointASTM D9350mlView DescriptionView Method
Free & Total GlycerinASTM D65845mlView DescriptionView Method
Gross Calorific Value of Coal and CokeASTM D586520mlView DescriptionView Method
Gross Calorific Value of Refuse-Derived FuelASTM E7115ml or 2 gramsView DescriptionView Method
High Temperature StabilityASTM D6468100ml View Method
Insoluble ImpuritiesCa 3a-4650gView DescriptionView Method
Mercaptan SulfurASTM D3227100ml View Method
Naphthalene HydrocarbonsASTM D1840100ml View Method
Oxygen ContentNA10gView Description 
Particulate ContaminationASTM D6217300mlView DescriptionView Method
Particulate Contamination (B100)ASTM D7321300mlView DescriptionView Method
Peroxide NumberASTM D3703200mlView DescriptionView Method
pHe of EthanolASTM D6423250ml View Method
Pour PointASTM D9780mlView DescriptionView Method
Proximate AnalysisASTM D514220g View Method
Pyrolysis SolidsASTM D757915gView DescriptionView Method
Silver Strip CorrosionIP 227, D404850ml View Method
Specific GravityASTM D405250mlView DescriptionView Method
Sulfated AshASTM D874200ml View Method
SulfurASTM D262220mlView DescriptionView Method
Sulfur (Bomb Method)ASTM D12950mlView DescriptionView Method
Sulfur DeterminationASTM D42395g View Method
Total Solids in BiomassASTM E17565gView DescriptionView Method
Total Sulfur of Refuse-Derived FuelASTM E77550mlView DescriptionView Method
Unsaponifiable MatterCa 6a-4050gView DescriptionView Method
ViscosityASTM D445100mlView DescriptionView Method
Visual InspectionASTM D4176900ml View Method
Water & SedimentASTM D2709, D1796100mlView DescriptionView Method
Water in Organic LiquidsASTM E106410mlView DescriptionView Method
Water InsolublesNA100ml  
Water Reaction of Aviation FuelsASTM D1094100ml View Method
Water, Coulometric Karl FischerASTM D630425mlView DescriptionView Method
Water, Volumetric Karl FischerASTM E20350mlView DescriptionView Method
Other Capabilities
  Want to know how much additive to use to get to a certian cloud point or cold filter plugging point?
Send us your additive and we'll blend it at specified amounts at each degree to obtain the desired effect. This service is available with B100, biodiesel blends or #2 diesel fuel.
  Our sulfur analyzer instrument can detect sulfur levels in any matrix down to .3 ppm. Please call if you have a specific matrix you'd like tested for sulfur levels.
  If you are experiencing fuel quality issues, we have a number of tests to identify the problem.
  • Bacteria Analysis
  • Water & Visual Clarity
  • % Blend check for B2, B5 and B20
  • Field test kits for Acid Number and Glycerin
To contact a project manager about a specific request please fill out this form or give us a call
First Name:  
Last Name:  
Email:  
Service Request*:  
It was because of these superior certification results that cartier replica sale originally started marking its watches with the watches sale designation ¨C and while the rolex replica certification's criteria is still commendable, Rolex today, apparently, possesses the manufacturing capabilities to push that omega replica uk even further, hence justifying once again the fake hublot term on the dials. As for the competition? Most notably, Omega has introduced its own new in-house testing procedures for the breitling replica sale line of movements, which are available for a much more limited, albeit constantly expanding, range of models ¨C like the rolex replica (hands-on and more details on the movement here).
Biodiesel Road
600 E 17th St S | Suite B | Newton, IA 50208 | Phone: 800-858-5227 | Fax: 641-792-7989